BSFMM - PS12260, POWER-SONIC RECHARGEABLE SEALED LEAD-ACID BATTERY

  • MSDS: BSFMM
  • Manufacturer: POWER SONIC CORP
  • Product Name: PS12260, POWER-SONIC RECHARGEABLE SEALED LEAD-ACID BATTERY
  • National Stock Number: 6140-01-346-8316
Product Identification

Product ID:PS12260, POWER-SONIC RECHARGEABLE SEALED LEAD-ACID BATTERY
MSDS Date:07/05/1992
FSC:6140
NIIN:01-346-8316
MSDS Number: BSFMM

Responsible Party
POWER-SONIC CORP
3106 SPRING ST
REDWOOD CITY, CA 94063-3929
US

Emergency Phone: 415-364-5001

Info Phone: 415-364-5001

Cage: 56309

Contractor
POWER-SONIC CORP
5242 REDWOOD CITY, CA 94063-3929 US

Telephone: 650-364-5001

Cage: 56309

Ingredients

SULFURIC ACID (SARA III)

CAS: 7664-93-9

RTECS: WS5600000

Fraction By Weight: 39.1%

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


LEAD (SARA III)

CAS: 7439-92-1

RTECS: OF7525000

OSHA PEL 0.05 MG/M3;1910.1025

ACGIH TLV: 0.15 MG/M3;DUST 9293

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


LEAD OXIDES

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:BATTERY NOT HAZ UNDER NORMAL
CONDITIONS TIL BROKEN.ELECTROLYTE CAUSES:SEV EYE/SKIN BURNS/CORNEA
DAMAGE/BLINDESS.SEV SKIN IRRIT/ULCERATION.BRONCHIAL
MEMBRANES/TUBES,NOSE/THRO INFLAMM.SEV BURNS/ULCERATI ON OF
MOU/THRO/ESOPH/STOMA;KIDNEY&INTESTDAMAGE.TEETH ERROSION.CONJ/RESP
INFECT/EMPHY/DIGEST DISTUR.LEAD POISONING.
Effects of Overexposure:CONCENTRATION AS LOW AS 5MG/M3 CAN CAUSE
COUGH/INCREASED RESPIRATORY RATE & IMPAIRED VENTILARY CAPACITY.
STINGING OF SKIN/BURNING SENSATION CAUSED BY DROPLETS/MIST. EYE
IRRITATION OCCURS @ CONC OF 1.1 -2.4MG/M3. TEETH MAY BECOME
DISCOLORED.
Medical Cond Aggravated by Exposure:NONE GIVEN BY MFG'S MSDS.

First Aid

First Aid:EYE:FLUSH W/LG AMTS OF COOL WATER OPENING EYELIDS FOR @ LEAST
15MIN.IF WEARING CONTACT LENS SEEK DOCTOR.SKIN:FLUSH W/ LG AMTS OF
COOL WATER FOR @ LEAST 15MIN.INCLUDING CLOTHING/SHOES.INHAL: REMOVE
TO FRESH AIR.GIVE ARTI RESP IF BREATHING STOPPED.KEEP
WARM&DRY.GIVE OXYGEN IF BREATHING HARD.ING:GIVE LG AMTS OF
WATER.DON'T INDUCE VOMIT.WASH OUT MOUTH/GARGLE TO WASH THRO.GIVE
MILK W/EGG WHITES OR VEG

Fire Fighting

Flash Point:NOT COMBUSTIBLE
Lower Limits:NA
Upper Limits:NA
Extinguishing Media:FOR FIRES IN AREA: DRY CHEMICAL, CARBON DIOXIDE,
WATER FOG, WATER.
Fire Fighting Procedures:WEAR NIOSH APPROVED SELF CONTAINED BREATHING
APPARATUS & FULL-COVER SULFURIC ACID RESISTANT CLOTHING.
Unusual Fire/Explosion Hazard:ACID REACTS VIOLENTLY W/METALS,NITRATES,
CHLORATES,CARBIDES,FULMINATES,PICRATES,& OTHER ORGANIC MATLS.
HYDROGEN GAS RESULTS FROM ACID/METAL CONTACT DIL IN WATER

Accidental Release

Spill Release Procedures:STOP FLOW OF MATERIAL.USE RESP PROTECTION IF
AREA NOT WELL VENTILATED.WEAR ACID-RESISTANT CLOTHING COVERING ALL
SKIN SURFACES.CONTAIN/ABSORB SM SPILLS W/VERMICULTIE,DRY
SAND/EARTH/SIMILAR MAT. ;DON'T USE COMBUSTIBLE MATL.USE
DIKE/DAMPUP FORLG SPILLS
Neutralizing Agent:W/LIME,SODA ASH,SODIUM BICARBONATE,ETC. DILUTE
CAUTIOUSLY W/LG AMT OF WATER

Handling

Handling and Storage Precautions:STORE COOL,DRY,VENTILATED AREA
PROTECTED FROM SEVERE WEATHER& W/UNLIMITED WATER SUPPLY.KEEP AWAY
FROM FIRE/SPARKS/ HEAT.STORE BATTERY <70F & NOT >140F
Other Precautions:ELECTROLYTE GIVES OFF LG AMTS OF HEAT WHEN MIXED W/
WATER.AVOID CONTACT OF BOTH BATTERIES' TERMINALS W/METALLIC MATLS/
ELECTRICAL CONDUCTORS/WATER TO AVOID SHORT CIRCUIT &
EXPLOSION.DON'T OPERATE BATT ERY OUTSIDE OF MFG'S RECOMMENDATION.

Exposure Controls

Respiratory Protection:NOT REQUIRED UNDER NORMAL CONDITIONS. WHEN
CONCENTRATIONS OF SULFURIC ACID IN AN AREA MAY EXCEED PEL, USE
NIOSH- APPROVED, FITTED, FULL FACE RESPIRATOR WITH APPROPRIATE
FILTER OR SELF- CONTAINED BREAT HING APPARATUS.
Ventilation:USE IN WELL VENTILATED AREA W/NO CROSS DRAFTS. VENTILATION
COMPONENTS MUST BE ACID & EXPLOSION RESISTANT.
Protective Gloves:ACID RESISTANT RUBBER/PLASTIC.
Eye Protection:ACID-RESISTANT GOGGLES W/FACE SHIELD.
Other Protective Equipment:GLOVES SHOULD HAVE ELBOW-LENGTH GAUNTLET &
ROLLED-OVER CUFF. ACID-RESISTANT APRON & BOOTS. EMERGENCY EYEWASH &
SHOWER.
Work Hygienic Practices:WASH HANDS AFTER USAGE OF ELECTROLYTE AND
BEFORE EATING/SMOKING/DRINKING.LAUNDRY CONTAMINATED CLOTHING/SHOES.
Supplemental Safety and Health
BATTERY NOT HAZARDOUS UNDER NORMAL CONDITIONS;HOWEVER, IF BROKEN
ELECTROLYTE IS HAZARDOUS. ELECTROLYTE WILL ATTACK SOME FORMS OF
PLASTICS,RUBBER,COATING THAT AREN'T ACID-RESISTANT. REACTIONS
W/POTASSI UM CYANIDE OR SODIUM CYANIDE RELEASE HYDROGEN CYANIDE
GAS. DO NOT WEAR CONTACT LENS WHEN WORKING W/SULFURIC ACID.

Chemical Properties

HCC:Z4
Boiling Pt:B.P. Text:237F,114C
Melt/Freeze Pt:M.P/F.P Text:-94F,-70C
Vapor Pres:9.95
Vapor Density:>1
Spec Gravity:1.280
Evaporation Rate & Reference:<1 (ETHER=1)
Solubility in Water:COMPLETE
Appearance and Odor:COLORLESS GEL, WITH SHARP, PENETRATING, PUNGENT
ODOR.
Percent Volatiles by Volume:0 @70F

Stability

Stability Indicator/Materials to Avoid:YES
COMBUSTIBLES, ORGANICS, STRONG REDUCING AGENTS, METALS, SULFUR TRIOXIDE
GAS, STRONG OXIDIZERS, WATER, METALS.
Stability Condition to Avoid:CONTACT W/COMBUSTIBLES & ORGANICS MAY
CAUSE FIRE & EXPLOSION. CONTACT W/METALS PRODUCES TOXIC SULFUR
DIOXIDE & HYGROGEN.
Hazardous Decomposition Products:SULFUR TRIOXIDE & DIOXIDE, SULFURIC
ACID FUMES, CO, HYDROGEN SULFIDE, HEAT.

Disposal

Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH FEDERAL/STATE/LOCAL
REGULATIONS.

Transport

Transport Information:49CFR 173.159 (D): A NON-SPILLABLE WET ELECTRIC
STORAGE BATTERY IS EXCEPTED FROM ALL OTHER REQUIREMENTS OF THIS
SUBCHAPTER IF: 1. THE BATTERY IS PROTECTED AGAINST SHORT CIRCUIT;
2. FOR BATTERIES MANU FACTURED AFTER SEPTEMBER 30,1995, THE BATTERY
AND THE OUTER PACKAGING MUST BE PLAINLY AND DURABLY MARKED
"NONSPILLABLE" OR :NONSPILLABLE BATTERY", AND 3. THE BATTERY MUST
BE CAPABLE OF WITHSTANDING T HE FOLLOWING TWO TESTS WITHOUT LEAKAGE
OF BATTERY FLUID FROM THE BATTERY: (I)VIBRATION TEST; (II) PRESSURE
DIFFERENTIAL TEST. PER MFR THESE BATTERIES CONFORM TO THE ABOVE
REGULATION AND ARE, THEREFORE , NOT REGULATED.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.